Controller Icon
Home Page
MIND 12 VOLT
A592 /A574 BRAIN
A466 UNIVERSAL
GEO 05
A382C SPRINT
A543 LYNX
BRAIN 03
Back
Controle Boards

LYNX A453

Adobe Icon

Download A453 Manual

Adobe Icon

Download Lynx 03/04 Manual

A453 Lynx 230V (24V - Lynx 03) for Single Motors.

  • Fitted as standard on all Lift 230V barriers
  • For pair of barriers see A466 Unix control unit page.
Lynx A453 Controller
Lynx 03 24V Controller

LYNX 03, 24V.

  • Designed with intensive use in mind.
  • Complete with toroidal transformer.
  • External IP55 housing.
  • Batteries (optional) can supply backup usage in event of power failure.
Technical Specifications. Lynx A453 230V. Lynx 03 24V
Power Supply Voltage (Vac) 230 (+6 -10%) - 50/60 Hz
Power supply Centrale (Vac) Not applicable 22 (+6-10%) -50/60 Hz
Absorbed Power (W) 50 3 Maximum
Motor Load (W) 500 80
Maximum Accessories Load (mA) 500 24 Vdc 500mA
Ambient Temperature ( °C) -20 °C +50 °C -20 °C +55 °C
Protection Fuses 2
Function Logic Automatic / 'stepped' Stepped automatic
Opening / Closing Time (seconds) 30 second fixed Through self learning during programming
Pause Time (seconds) Trimmer adjustable (2 to 90 sec.) Through self learning during programming
Thrust Force Trimmer adjustable 2 levels selected by dip-switch
Thrust Time (seconds) 1 second fixed Not applicable
Reversing Time (seconds) 2 second fixed Not applicable
Slow-Down Time (seconds) 1 second fixed Not applicable
Terminal Board Inputs Open / closing photocells / stop / open and closing limit switch / mains power + earth / open-close separate input 22 Vac power supply/battery power supply/start/CLOSE only input/stop/opening safety devices/closing safety devices/opening limit switch/closing limit switch
Selectable Functions Not Applicable Electronic clutch/automatic closing/slow-down on opening/limit-switch/condo function/START command/slow-down time/courtesy light or indicator light/limit switch
Rapid Connector Genius 5 PIN receiver
Sensor Connector Anti-crushing sensor Not applicable
Terminal Board Outputs 24 vdc accessories power supply / courtesy light / lamp / motor 24Vdc accessories/24 Vdc motor / electric lock / 24 vdc lamp - courtesy light.
Transformer characteristics Not Applicable Primary 230 Vac, secondary 22 Vac/800VA
Optional battery characteristics Not Applicable 12V - 4Ah. Dimensions: 90 x 70 x 108mm
External Housing Not Applicable 305 x 225 x 125mm. IP55
Sprint Batteries
Sprint 03 24 Volt
Optional batteries for backup
Code - A485