Controller Icon
Home Page
MIND 12 VOLT
A592 /A574 BRAIN
A466 UNIVERSAL
GEO 05
A382C SPRINT
A543 LYNX
BRAIN 03
Back
Controle Boards

Brain 15 24V Controller

Adobe Icon

Download Manual

24 Volt Controller

  • Designed for intensive use.
  • For single or pair of swing gates.
  • Complete with transformer.
  • External housing.
  • Can be used with optional Battery pack 6100144 for back-up in case of power failure.
  • Bus interface (Optional) must be used for NON Bus Photocells or Loop detector.

6100212 Brain 13

6100234 BUS Interface.

6100144 Battery Kit

Technical Specifications. Brain 13, 24V.
Power Supply Trasformatore (Vac) 230 (+6 -10%) - 50 Hz
Power Supply Centrale (Vac) 24 Vac Nominal (1)
Absorbed Power (W) 20
Maximum Motor Load (W) 2 x 150
Maximum Accessories Load (BUS) 24 Vdc 400 mA
Electric Lock 12 Vac or 24 Vdc
Maximum lamp Load 24 Vdc 15W maximum
Ambient Temperature ( C) -20 +55
Protection Fuses F1 = Self resetting; F2 = T2A-250V
Function Logic A,E,AP,EP,A1,B,C
Opening / Closing Time Through self-learning during programming
Pause Time Varies According To Learning (Max 10 Min)
Leaf Delay Time At Closing Fixed or Varies According To Learning
Thrust Force 4 levels selected by Dip Switches
Selectable Functions Logics, Speed (High, Low)
Terminal Board Inputs  
Rapid Plug Genius 3 PIN receivers
Terminal Board Outputs 24 vdc accessories
Transformer Characteristics Primary 230Vac - secondary 2
Container For External Use 305